McMurdo Dry Valleys LTER
Published on McMurdo Dry Valleys LTER (https://mcm.lternet.edu)


CAAM_ICET

Description: 

CAAM - Ice Temperature

File: 

File CAAM_ICET.csv

Methods: 

See task list

Instrumentation: 

Fenwall Thermisters (192-102DEW-A01) and Caddock Tetrinox(TF050N) hi precision resistor (10Kohm) with +-5ppm/celcius and 0.01percent Resistor

Quality Assurance: 

Fenwall Thermisters (192-102DEW-A01) and Caddock Tetrinox(TF050N) hi precision resistor (10Kohm) with +-5ppm/celcius and 0.01percent Resistor

Variables (click to expand): 

DATASET CODE
  • Label:
  • Definition: Code for given set of information for Canada Glacier meteorology station
  • Type: Nominal
  • Missing values: None specified
METLOCID
  • Label:
  • Definition: Location code for Canada Glacier meteorology station
  • Type: Nominal
  • Missing values: None specified
DATE_TIME
  • Label:
  • Definition: Date/time of sample (New Zealand DST, +13 UTC)
  • Type: Date/time
  • Date format: MM/DD/YYYY HH:MI
  • Missing values: None specified
ICET50CM
  • Label:
  • Definition: Ice temperature at 50 cm depth
  • Type: Physical quantity
  • Unit: celsius
  • Maximum: Not specified
  • Minimum: Not specified
  • Precision: 0.01
  • Missing values:
    • Null = See comments
ICET1M
  • Label:
  • Definition: Ice temperature at 1 meter depth
  • Type: Physical quantity
  • Unit: celsius
  • Maximum: Not specified
  • Minimum: Not specified
  • Precision: 0.01
  • Missing values:
    • Null = None given
NEWICET_25CM
  • Label:
  • Definition: Ice temperature at 25cm
  • Type: Physical quantity
  • Unit: celsius
  • Maximum: Not specified
  • Minimum: Not specified
  • Precision: 0.01
  • Missing values:
    • Null = See comments
NEWICET_50CM
  • Label:
  • Definition: Ice temperature at 50cm
  • Type: Physical quantity
  • Unit: celsius
  • Maximum: Not specified
  • Minimum: Not specified
  • Precision: 0.01
  • Missing values:
    • Null = See comments
NEWICET_75CM
  • Label:
  • Definition: Ice temperature at 75cm
  • Type: Physical quantity
  • Unit: celsius
  • Maximum: Not specified
  • Minimum: Not specified
  • Precision: 0.01
  • Missing values:
    • Null = See icet comments
NEWICET_100CM
  • Label:
  • Definition: Ice temperature at 100cm
  • Type: Physical quantity
  • Unit: celsius
  • Maximum: Not specified
  • Minimum: Not specified
  • Precision: 0.01
  • Missing values:
    • Null = see comments
ICET_COMMENTS
  • Label:
  • Definition: Noted comments by the investigator about the particular measure of ICET_
  • Type: Nominal
  • Missing values: None specified

Source URL: https://mcm.lternet.edu/content/caamicet