GADM_RADN
Description:
Garwood Valley Solar Radiation Measurements and Units
File:
Methods:
See tasks list file at  http://www.mcmlter.org/data/meteorology/tasks/task_lists.htm
Instrumentation:
PAR: LI-COR model 190SB quantum sensor. 
Solar Flux (incoming): LI-COR model L1200X silicon pyranometer 
Solar Flux (outgoing):  LI-COR model L1200X silicon pyranometer 
Variables (click to expand):
DATASET_CODE
- Label:
 - Definition: Code for given set of information for Lake Vida meteorology station
 - Type: Nominal
 - Missing values: None specified
 
METLOCID
- Label:
 - Definition: Location code for Lake Vida meteorology station
 - Type: Nominal
 - Missing values: None specified
 
DATE_TIME
- Label:
 - Definition: Date/time of sample (New Zealand DST, +13 UTC)
 - Type: Date/time
 - Date format: MM/DD/YYYY HH24:MI
 - Missing values: None specified
 
PAR
- Label:
 - Definition: Photosynthetically active radiation
 - Type: Physical quantity
 - Unit: micromols/second/meter2
 - Maximum: Not specified
 - Minimum: Not specified
 - Precision: 0.1
 - Missing values: 
- Null = See comments
 
 
SWRADIN
- Label:
 - Definition: Incoming shortwave radiation/solar flux
 - Type: Physical quantity
 - Unit: W/m2
 - Maximum: 900
 - Minimum: 0
 - Precision: 0.1
 - Missing values: 
- Null = See comments
 
 
SWRADOUT
- Label:
 - Definition: Outgoing shortwave radiation/solar flux
 - Type: Physical quantity
 - Unit: W/m2
 - Maximum: 900
 - Minimum: 0
 - Precision: 0.1
 - Missing values: 
- Null = See comments
 
 
RADN_COMMENTS
- Label: radiation comments
 - Definition: Noted comments by the investigator about the particular measure of radiation
 - Type: Nominal